How to calculate a heat accumulator for a solid fuel boiler and connect it

The use of heat accumulators for the heating system allows optimizing the combustion of solid fuels in boilers. In simple words, if there is a buffer tank - a heat accumulator - the homeowner does not need to visit the boiler room often, and the firewood will burn in an optimal manner. But for this, the container needs to be selected correctly, and then connected to the heating equipment, which will certainly cause difficulties for an ignorant person. Therefore, it is worth understanding in detail what a heat accumulator for a solid fuel boiler is, how to select it and connect it to the heating of a private house.

What is buffer capacity

In fact, a heat accumulator intended for a heating system is an ordinary metal tank of rated capacity, covered with a thermal insulation layer. In the simplest factory-made models there are only pipes for connecting the coolant and sleeves for installing thermometers. In more expensive buffer tanks, thermometers are already built-in, and the most expensive products are equipped with heat exchangers in the form of coils. The structure of such a heat accumulator is shown in the figure:

As you can see, the design of the buffer tank is not particularly complex, which is why various craftsmen have adapted to making it with their own hands, which is discussed in a separate topic.

The purpose of the coils is to heat water to provide hot water supply and connect alternative sources of thermal energy - solar collectors. It is clear that this function is in demand only under favorable weather conditions in the region of residence. In general, the buffer tank for a heating boiler is designed to solve the following problems:

  1. Creating conditions for the operation of a TT boiler with maximum efficiency and minimal emissions into the atmosphere.
  2. Comfortable operation of the heat generator, when you do not need to add firewood to the firebox every 4-6 hours, including at night.
  3. Heating and supply of drinking quality water to 1-2 consumers (optional).

Most manufacturers of heating equipment operating on solid fuel indicate in the accompanying documentation that it is highly desirable to connect a heat accumulator to the TT boiler. The reason is this: the unit achieves its greatest efficiency when the operating mode is close to the maximum. And since the excess heat generated needs to be placed somewhere before being supplied to the heating system, you will need a buffer tank with water.

Without a thermal accumulator, we try in every possible way to “strangle” the thermal unit, limiting the supply of air for combustion. Not only does this reduce its efficiency to 40% (like a potbelly stove), but it also causes the release of toxic carbon monoxide into the atmosphere. Because of this, some European countries have banned the burning of wood and coal in heating boilers without a buffer tank.

With more rare visits to the furnace room, everything is clear: the heat accumulated in the tank will be spent on heating the house for a long time, provided that its volume is correctly calculated. In addition, when a solid fuel boiler works together with a heat accumulator, the likelihood of overheating and boiling of water in the unit jacket is reduced to almost zero.

In addition to interacting with wood heat generators, heat accumulators can also be used with electric boilers. This makes sense when the electricity consumed at night is calculated at a tariff that is 2-3 times lower than usual. During the period of time that this tariff is in effect, the electrical installation will be able to fully “charge” the thermal accumulator, and it will begin to release this energy to heat the house during the day.

With this option, the results of the previous calculation of the power of the electric boiler will have to be doubled so that its heat transfer is sufficient to heat the house and load the tank at the night rate.

Calculation of buffer capacity

The main criterion by which a buffer tank for a solid fuel boiler is selected is its volume, determined by calculation. Its value depends on the following factors:

  • heat load on the heating system of a private house;
  • heating boiler power;
  • expected duration of operation without the help of a heat source.

Before calculating the capacity of the heat accumulator, you need to clarify all the listed points, starting with the average thermal power that the system consumes during the winter period. The maximum power should not be taken for calculation; this will lead to an increase in the size of the tank, and therefore to an increase in the cost of the product. It’s better to endure the inconvenience for a few days a year and load the firebox more often than to pay a crazy price for a large heat accumulator that will be used irrationally. And it will take up too much space.

Expert opinion. To provide thermal energy to a house with an area of ​​200 m², a buffer tank containing 1 ton of coolant, which is a volume of 1 m³, is sufficient. The statement is true for the central part of the Russian Federation; in more southern or northern regions the situation will be different.

Normal operation of a heating system with a heat accumulator is impossible when the heat source has a small power reserve. In this case, it will never be possible to “charge” the battery completely, since the heat generator must simultaneously heat the house and load the tank. Remember that the selection of a solid fuel boiler for connection with a heat accumulator assumes a double thermal power reserve.

It is proposed to study the calculation algorithm using the example of a house with an area of ​​200 m² with a boiler downtime of 8 hours. It is assumed that the water in the tank will heat up to 90 °C, and during heating operation it will cool down to 40 °C. To heat such an area in the coldest time, you will need 20 kW of heat, and its average consumption will be about 10 kW/h. This means that the battery must accumulate 10 kW/h x 8 hours = 80 kW of energy. Next, the volume of the heat accumulator for a solid fuel boiler is calculated using the formula for the heat capacity of water:

m = Q / 1.163 x Δt, where:

  • Q is the estimated amount of thermal energy that needs to be accumulated, W;
  • m – mass of water in the tank, kg;
  • Δt – the difference between the initial and final temperatures of the coolant in the tank is 90 – 40 = 50 °C;
  • 163 W/kg °C or 4.187 kJ/kg °C – specific heat capacity of water.

For the example under consideration, the mass of water in the heat accumulator will be:

m = 80000 / 1.163 x 50 = 1375 kg or 1.4 m³.

As you can see, as a result of calculations, the dimensions of the buffer capacity are larger than what the expert recommends. The reason is simple: inaccurate initial data were taken for the calculation. In practice, especially when the house is well insulated, the average heat consumption per area of ​​200 m² will be less than 10 kW/h. Hence the conclusion: in order to correctly calculate the dimensions of a heat accumulator for a solid fuel boiler, it is necessary to use more accurate initial data on heat consumption.

For reference. There is also an enlarged calculation method, according to which for each kW of boiler thermal power there is 25 liters of heat accumulator volume.

Distributes energy consumption and saves fuel

The benefits of connecting a heat accumulator are obvious. As a result, the boiler needs to be heated much less frequently than with a conventional system. This saves not only fuel, but also time and physical effort.

If we are talking about a heating device that runs on electricity, then a heat exchanger with smart electronics will help you save money. It will distribute energy consumption evenly and expediently.

Another important advantage: since the heating system with a heat accumulator will operate stably, excluding sudden temperature changes, the service life of all equipment will be significantly extended. Investment in organizing such an energy saving system will pay off already in the first heating season.

Investment in organizing such an energy saving system will pay off already in the first heating season.

Selection of heat accumulator

The remaining criteria for choosing a container are not so important and mainly relate to different options. One of them is a built-in coil that heats water for household needs. It may be useful if there are no other means of heating, but for high costs in the DHW network this method is definitely not suitable. In addition, the heat exchanger will take away part of the “charge” of the heat accumulator, reducing the autonomous operation time of the heating.

A useful option is a heating element built into the top of the tank, capable of maintaining the temperature of the coolant at a certain level. Thanks to electric heating, the system will not defrost in the event of an accident and will even be able to heat the house for some time after the battery has been “discharged” and the boiler has not yet been started.

The second coil for connecting the solar system is useful only in the southern regions, where solar activity will allow the heat accumulator to be loaded. But what you should pay attention to when selecting is the operating pressure of the tank. It should be taken into account that most solid fuel boilers are designed for pressure in the jacket up to 3 Bar, which means that the buffer tank should easily withstand the same amount.

Connection diagrams

There are many ways to connect a solid fuel boiler with a heat accumulator and a heating system. But they are all derived from the basic circuit shown below. With its help, it is easy to understand how these units work in pairs, and then install everything yourself.

A heat source running on solid fuel has a traditional boiler circuit with a mixing unit, whose task is to prevent the supply of cold coolant to the boiler. Then the supply and return pipelines are connected to the buffer tank, respectively, from above and below. In the same way, a heating system, also equipped with a mixing unit, is connected to the heat accumulator. Its purpose is to maintain the required water temperature in the system, adding part of the hot coolant if necessary.

Important point. The actual performance of the boiler circuit circulation pump should be slightly higher than that of the heating network pumping unit. Compliance with this condition will allow the flows inside the heat accumulator to move in the right direction (shown in the diagram with white arrows).

In fact, the network pump will be more powerful than the boiler pump and here's why. The resistance of the network of pipelines and radiators is higher than 3-5 m of pipe from the solid fuel boiler to the heat accumulator. The unit needs higher power and pressure to overcome this resistance. Therefore, a weaker boiler circuit pump can provide higher flow rates, you just need to configure both units correctly. There are 2 options to resolve the issue:

  1. When using 3-speed pumps, you can adjust their performance by switching speeds.
  2. Place a balancing valve at the inlet of the return from the system into the buffer tank, which can be used to make adjustments.

Simultaneous heating of heating devices and layer-by-layer loading of a heat accumulator is possible when the flows inside the tank move horizontally with a slight predominance from the side of the solid fuel boiler. The question arises - how to check this? The answer arises: thermometers must be installed at both return inlets to the tank (as in the diagram) and adjustments must be made by switching pump speeds or rotating the balancing valve. Important condition: the three-way valve of the heating network must be fully opened manually.

By adjusting it is necessary to ensure that the temperature at the inlet to the heat accumulator (T1) is less than at its outlet (T2). This means that part of the hot water goes to “charging” the battery. You can learn more about all the points from an expert by watching the video:

Alternative scheme

This scheme for connecting a buffer tank and a solid fuel boiler was proposed by one of the participants in the popular forum. Its peculiarity is that in the event of a power outage, the operability of the circuit remains, although you have to pay for this with increased diameters of steel pipes. The figure below shows the connection of a heat accumulator to a closed heating system, but during installation it is better to make it open, as the author himself says.

Briefly, the essence is this: thanks to the T-shaped input on top of the tank, the radiators are simultaneously heated and the thermal accumulator, made by hand, is “charged”. The boiler circuit pump is controlled by a clip-on sensor on the supply line, turning on the unit when it reaches a temperature of 60 °C. The circulation in the network depends on the room thermostat to which the network pump is connected.

Note. The proposed strapping scheme was tested by its creator from his own experience. All details of its installation and operation are described by the author on the forum

Functionality of heat accumulators

The principle of operation of the equipment is that during operation of the boiler, part of the heat is used to heat the coolant from an additional tank. The connected tank has good thermal insulation and perfectly retains the resulting heat. After the boiler is turned off, the water in the heating system cools down, and the control devices turn on the pump that supplies hot water from the storage tank.

These cycles continue as long as the water temperature in the auxiliary tank remains high enough. The total duration of operation of the system without turning on the boiler depends on the volume of the additional capacity. In practice, it allows you to heat rooms from several hours to 2 days.

The heat accumulator performs the following functions:

  1. It accumulates heat coming from the system boiler and releases it over time to heat the rooms of the room.
  2. Prevents the possibility of boiler overheating by removing excess heat from the exchanger.
  3. Allows you to easily combine different heating devices (electric, gas, solid fuel) into a common system.
  4. Helps improve the performance of heating equipment, reducing fuel consumption and improving efficiency.
  5. In systems with solid fuel boilers, it eliminates constant monitoring of the condition of heating equipment. By heating the coolant in an additional container, homeowners can forget about the need to constantly load fuel into the boiler.
  6. It is a source of hot water for domestic needs.


Heating system diagram
How profitable a heating system with a heat accumulator is can be seen using this example.

Let's assume that a 10 kW boiler is installed in the heating system. Every 3 hours it is necessary to load firewood. This does not fit into the plans of the homeowners. To lengthen the breaks between loads, it is necessary to use a larger boiler. But in this case, the coolant may boil, since the system will not have time to remove all the generated heat.

Connecting a heat accumulator with a capacity of about 200 liters easily solves the problem. The equipment allows you to accumulate 110 kW of energy provided that the boiler is fully and frequently loaded. Subsequently, the accumulated heat will maintain a comfortable room temperature for about 10 hours. There is no need to load the boiler with fuel all this time.

Rating
( 1 rating, average 5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]