Gas wall-mounted boilers Buderus
Models Logamax U042, U044, GB072, GB172. With open and closed combustion chamber. Methods of repair and service, adjustment of operating parameters. Maintenance recommendations.
Gas heating boilers Vaillant
Models: floor-standing Atmovit exclusiv, wall-mounted condensing Ecotec plus.
Service, maintenance, settings of functional components. Hydraulic diagrams. Gas wall-mounted boilers Ariston
Models Clas, Clas Evo, Genus.
Recommendations for repair, maintenance and service. Elimination of errors and malfunctions. Setting and adjustment methods. Gas boilers Immergaz
Models Eolo Star, Eolo Mini, Nike Star, Nike Mini, Mithos. Repairs and adjustments. Installation, assembly and connection. Settings of operating modes and additional equipment.
Boilers Kentatsu Furst
Wall-mounted models Nobby Smart. Condensing Smart Condens. Floor standing Sigma, Kobold. Solid fuel Elegant, Vulkan. Malfunctions and error codes. Description and characteristics.
Possible breakdowns of Mora Top gas boilers, which are visible on the display
Error E0
— The device is blocked. There is no gas supply. The burner is not active. The pump is turned off. The internal elements of the control and regulation unit are broken. Needs replacement.
Error E1
— The boiler is blocked. The switches do not close. Due to this, gas is not supplied, the burner is inactive, and the pump is turned off. Small amount of water in the heating system. The filter may be clogged. It needs to be cleaned. Small amount of water in the heating system. Pump failure. Needs replacement. There is not enough water in the heating system. The pump, instead of the recommended 2nd or 3rd stage, is installed on the first. Set the correct mode. Also, error code E1 may appear in the following cases: Presence of air pockets. It is necessary to pump water so that the recommended pressure value is established in the system. When switching heating and hot water modes, bleed off excess air. Reboot the unit. Problems with the axis of the flow switch, it is either inactive or completely motionless. It is necessary to disassemble the switch box from the flow sensor housing. Try to free the jammed axle. If this does not work by turning the boiler on and off, push it with your finger. The gap between the axle and the drive arm and the switch is too large. The position of the plastic arm for transmitting motion must be set correctly. The switch is broken. Needs replacement. The electrical connection between the switch and the control and regulation unit is broken. The chain needs to be restored. Check the wires.
Error E2
— Mora’s boiler was stopped due to an accident. The gas supply is interrupted. After the flame is turned off, the device tries to start again. The pump does not turn off while the device is trying to start working. Then he gets up. The flame went out because there was no gas supply. Click the Reset button. Due to the fact that the burner is very dirty, the gas supply is difficult. In this case, partial combustion of the flame can be observed. The gas supply port needs to be cleaned. The electrode is broken or the electrical connection line is damaged. Make a replacement. The ignition transformer is broken or the electrical connections are damaged. Make a replacement. Absence or partial contact in the electrical connection circuit of the ignition transformer and the control and regulation unit. Check the presence of the contact if you need to restore it. The phase and zero in the network are mixed up. Connect the boiler correctly. The backdraft fuse tripped due to too high a temperature rise due to leakage of combustion products. This is possible with complete or partial obstruction of the chimney. Clean the outlet pipes and chimney. To start, press the reset button. Also, error code E2 may occur in the following cases: The reverse thrust fuse is broken. Needs replacement. The electrical connection circuit of the reverse thrust fuse is damaged. Check connection. Restore. Lack of contact between the control unit backdraft fuse. Restore contact. The emergency thermostat tripped because the heating water temperature exceeded the maximum permitted value. Incorrect gas supply. Find out the reason. Eliminate. Emergency thermostat failure. Check its operation. At 95 degrees it should open. Install a new one if necessary. There is no electrical connection contact for the emergency thermostat. Check and fix. Poor or no contact between the emergency thermostat and the control and regulation unit. Check and replace if necessary. The ignition electrode is not installed correctly. Install correctly, taking into account that the distance between the end of the electrode and the plate is normally 3-4 mm. The gas valve did not open. The result is that the flame goes out. For diagnostics, it is necessary to check the contact of the main gas valve convector in the control unit. Replace if necessary.
Error E3
— The heating water temperature sensor is open. The device does not turn on in both modes. The gas supply to the burner is interrupted, as a result there is no flame, the pump is not turned on. The heating water temperature sensor is broken. Needs replacement. The sensor has no contact. Check the connection. Also, error code E3 may occur in the following cases: Problems with the electrical connection circuit of the temperature sensor. Check and fix. There is no contact between the temperature sensor and the control and regulation unit. Contact needs to be restored.
Error E4
— The service water temperature sensor is not closed. The Mora gas boiler operates in both modes. Instead of the sensor responsible for the temperature of the domestic water, the heating temperature sensor starts working. Accordingly, problems arise with regulating the required temperature in the DHW circuit. Also, error code E4 may appear in the following cases: The DHW sensor is faulty. Needs replacement. There is no contact with the temperature sensor. Check and restore. There is no contact in the electrical connection circuit of the temperature sensor. Check and restore. There is no contact between the temperature sensor and the control and regulation unit. Contact needs to be restored.
Error E5
— Failure in the safety module. The unit was stopped due to an emergency. With this error, the burner turns off and the flame goes out due to a gas supply interruption. The pump runs continuously. The emergency thermostat is triggered because the heating water temperature exceeds the maximum permissible value. This cuts off the gas supply. To eliminate it, you need to understand why the overheating occurred. Emergency thermostat failure. It is necessary to check its operation; at temperatures below 95 degrees it should be closed. If the failure is confirmed, replacement is required. The electrical connection circuit of the emergency thermostat is broken. Requires verification and restoration of operation. There is no contact between the emergency thermostat and the control and regulation unit. Troubleshooting and restoration required. Pressure switch connection missing. It is necessary to check the patency of the exhaust path for combustion products or the supply of clean air. Fix the problem. Also, error code E5 may occur in the following cases: The pressure switch is broken. There is no connection to it when the fan is running. A new switch needs to be installed. Problems in the electrical connection circuit of the pressure switch. Check and restore circuits. There is no contact between the pressure switch and the control and regulation unit. Restore contact. The tube connecting the pressure switch and the fan is either disconnected or damaged. It is necessary to check and install a new one if necessary. Perhaps the fan does not start working. The engine does not work. The impeller bearing has lost its mobility. The valve does not work due to any mechanical damage. If this problem occurs, the fan must be checked and replaced. There is no contact in the fan electrical connection circuit. There is no set speed of rotation of the fan blades. Check and fix. There is no contact between the fan and the control and regulation unit. To set up a contact.
Possible breakdowns of Mora Top gas boilers that are not displayed on the screen
The device cannot gain the power required for operation - At the same time, the temperature of the water in the hot water supply or for heating does not heat up to the set value.
The Mora Top boiler always switches to minimum power mode when operating - Problems in the electrical connection circuit between the modulator and the coils. Check the cable and contact in the control and regulation unit. The modulator on the coil is broken. To eliminate this problem, a complete replacement of the gas valve is required. The unit is not configured; its minimum and maximum capacities are set incorrectly. Re-adjustment of these parameters is required.
The device does not work in DHW mode - The burner does not turn on, there is no water heating. Poor water supply for household needs. The DHW filter is very dirty. It needs cleaning. The differential valve is very dirty. It needs cleaning. Water supply pressure is lower than required. To fix the problem, you need to increase the water supply pressure. If there is sufficient water pressure for the domestic hot water supply, the three-way valve does not switch. Check the water passage between the differential valve and the three-way valve. Clean if necessary. The 3-way valve is stuck. Try to fix the problem by turning the water supply to the hot water supply on and off. If this procedure is unsuccessful, install a new valve. The integrity of the membrane in the hydraulic part of the three-way valve may be damaged. A new one needs to be installed. The water supply is sufficient, the three-way valve switches from mode to mode. Check the clearance between the 3-way valve shaft, the motion transfer arm and the switch. Perhaps it's too big. Adjustments are required. Damage to the DHW switch. Needs replacement. The problem is in the electrical connection between the switch and the control and regulation unit. Restore the chain.
The wall-mounted boiler Mora has problems with domestic hot water, the working burner does not heat the water for household needs or is insufficient - With good water supply pressure, the water in the taps is not heated to a sufficient quantity. The problem is a heavily contaminated secondary heat exchanger. It needs cleaning. When the boiler is operating, water leaks out through the safety valve.
The following problems occur during operation of the device. After the heating water has heated to the required temperature, the pressure increases to two and a half bar. After this, the safety valve is activated and part of the water is discharged through it. In this case, when the water in the heating system cools, the pressure drops below the maximum permissible minimum value. Problems with the expansion tank. There may be a violation of its tightness. And it is necessary to check the valve, and if it is damaged, install a new one. After this, you need to pump in the pressure set by the manufacturer. The membrane in the expansion tanks is damaged. A new expansion tank needs to be installed.
The water supply pressure for household needs is so high that it increases the pressure in the heating system to two and a half bar. It is necessary to check the valve on the hydraulic unit to replenish the heating system; it may be open. When the device operates in automatic mode, air pockets are not removed. The valve cap is too tight. Check this and unscrew it if necessary.
___________________________________________________________________________________________
___________________________________________________________________________________________
Borino, ZhMZ, Siberia, Alfa Kalor, Termotechnik. Adjustment of gas automatic equipment Eurosit 630. Replacement of thermocouple and maintenance of pilot burner.
Models Luna, Luna 3 Comfort, Luna Duo Tec (F/Fi). Double-circuit, turbocharged. Recommendations for eliminating errors and malfunctions. Settings and adjustment of operating modes.
Models ZWC, ZSA, ZSC, ZWR, Gaz 5000, Gaz 3000 W ZW, WBN 6000. Wall-mounted, double-circuit. Repairs, adjustments and malfunctions. Settings for functions and modes.
Deluxe Coaxial, Deluxe Plus, GA models. Errors and problems. Working with Xital remote control. System control. Adjustment of work by temperature and pressure.
The structure and internal design of Czech gas boilers Mora Top made it possible to create a new generation of heating equipment that optimally complies with European and domestic standards.
The Mora manufacturer's line includes mounted and floor-mounted units, differing in different technical characteristics, operating principles and performance.
Review of Mora floor standing boilers
Mora Top floor-standing gas heating boilers are presented in more than ten modifications, the main difference of which is the type of burner and combustion chamber used.
To increase performance and heat transfer, it is recommended to use antifreeze. The heat exchanger and internal structure are designed taking into account the use of this liquid as a coolant.
As practice shows, the Czech water-heating energy-independent floor-mounted instantaneous gas heating boiler Mora Top is the optimal solution for heating country houses. The absence of complex automation, electricity-dependent components, high productivity - all this distinguishes the equipment of this series.
Carrying out installation work
Mora gas appliances are designed in such a way that installation and maintenance of boilers are as simple and easy as possible.
All volatile models have a self-diagnosis function. Information about all violations is displayed on the LCD display. The boilers are equipped with Mora equipment. As a result, automation, burner and other components ensure stable and long-term operation. Commissioning and adjustment of the boiler is carried out as follows:
- Volatile boilers are connected to the network. The self-diagnosis function starts automatically. The controller checks the presence of pressure in the heating system and gas pipeline. When deviations are found, a signal is issued in the form of a digital value. After troubleshooting, the boiler starts up.
- Non-volatile units do not have self-diagnosis functions, automatic flame ignition, etc. Therefore, before starting up and putting the equipment into operation, the company representative must ensure that all installation recommendations are followed. It is mandatory to install a water treatment system and a safety group; you may need to connect an expansion tank and a circulation pump.
Czech Mora gas boilers generally start up without any difficulties, but there are exceptions, mainly related to transportation or installation problems.
One of the common malfunctions of a double-circuit boiler is the failure of the thermocouple. After replacement, the functionality of the equipment is fully restored.
Why you should buy a Mora boiler
Mora's boilers have something that other manufacturers often miss - an understanding of the complexities and peculiarities of working in domestic conditions.
A potential buyer is also attracted by the possibility of choosing a suitable model. A huge range of models is presented: from 15 to 750 kW. You can choose a fully automatic installation and a classic boiler without complex automation. Simple operating rules also ensure the popularity of Czech Mora models.
The company Mora Top sro acquired characteristics close to its modern form in 2000 as a subsidiary of a joint stock company with a similar name - Mora Moravia. But at the beginning of the last century, one of the boilers of the above-mentioned enterprise was manufactured in the amount of hundreds of thousands of units per year. By the way, it was the Meteor boiler that became the first heating equipment in the world, the manufacture of which took place abroad under a license agreement. In 1924, the Soviet government decided to produce this type of boiler in St. Petersburg (then Petrograd).
In 2003 it gained independence, which was strengthened in 2004 with the start of construction of a new plant. In the spring of 2006, the production and technical base of the Mora Top enterprise acquired the shape of today. But the plans of the company’s management include the commissioning of additional production lines, which will lead to an increase in the number of products produced by more than three times. However, already now the plant’s production capacity allows it to produce about one hundred thousand water heaters and about fifty thousand gas boilers per year.
The quantity of products and their quality indicators determine the fact that Mora Top heating equipment is distributed not only in the Czech Republic, but is also exported to Romania, Bulgaria, Poland, Slovakia and the countries that once made up the Soviet Union.
The product range of the enterprise consists of the following categories: gas wall-mounted boilers - Titan (can be equipped with additional equipment, has an operating power of 14.8 kW, is immune to power surges, equipped with safety systems that ensure complete operational safety); electric boilers - Electra 8 (smart electric boiler, which is controlled by a microprocessor panel and can operate in more than ten functional modes; power from 2.5 to 7.5 kW); indirectly heated storage water heaters - 100 NTR (they are a water heating addition to heating boilers); combined storage water heaters - E 100 NTR (in addition to the ability to receive hot water from the energy of a heating boiler, they can heat it using a built-in electric element); wall-mounted instantaneous gas water heaters - Vega (very compact, available with power from 17.3 to 26.4 kW); floor-standing gas boilers with atmospheric burner - SA 20–60 (Classic series, fourteen different types with power from 15 to 50 kW); floor-standing boilers with forced-air burner - VL100 - VL750 (sixteen types with power from 103 to 750 kW).
Modern gas boilers are quite complex technological equipment. With proper care and proper handling, the gas boiler will serve for a long time without any failures. However, even the most expensive and functional equipment has its resource, after which various types of malfunctions begin to appear.
Knowing the main causes of problems and the procedure for eliminating them, you will be able to repair your gas boiler yourself. This is a very painstaking, responsible, but in most cases relatively uncomplicated work.
First of all, it is necessary to establish why any malfunctions may occur in the operation of gas heating boilers. A number of different factors can lead to problems.
Electricity
Modern gas boilers are equipped with various automation equipment. These products, in turn, are powered by electricity. And, despite the fact that it is already the 21st century and systems for the use of alternative energy sources are being actively developed all over the world, the problem of the stability of power grids remains relevant for many regions, especially for remote villages and all kinds of holiday villages.
A sudden shutdown or a strong surge in electricity is one of the main enemies of any modern gas boiler.
To avoid all the associated troubles, buy a high-quality stabilizer in advance. Do not spare money to purchase this device - cheap models are of little use, so it is better to immediately allocate funds to purchase a good stabilizer from a well-known manufacturer. Rest assured, if the automation breaks down, you will spend much more money on its repair and replacement.
Water
At home, wall-mounted models of gas boilers are often used. Such devices are simultaneously responsible for heating the premises and preparing hot water.
The design of wall-mounted boilers includes a flow-through heat exchanger. Low-quality hard water with various inclusions is the main enemy of the gas boiler heat exchanger. Moreover, under the influence of low-quality water, the heat exchanger can fail in just one season.
To prevent such damage, install special filters. The best option is a complete water purification system. With it, your boiler will work for as long as possible, and using purified water is much safer for your health.
Installation errors
Any knowledgeable person will tell you: the installation and piping of gas heating equipment should be carried out exclusively by qualified specialists.
Even the slightest errors at the stages of installation and connection of equipment can lead to irreversible consequences. For example, incorrectly performed piping in the case of a cast-iron gas boiler with a power of more than 50 kW will lead to the fact that the unit will simply crack at low temperatures.
Therefore, if you are not an experienced gas installer, entrust the installation of the boiler to professionals - this way you will save yourself from many problems in the future.
Weather
Adverse atmospheric conditions can also lead to many different problems. During frosty winters, people turn on the heating at almost full power. This leads to a significant decrease in pressure in the gas pipeline system. As a result, boilers cannot reach their full potential.
You won’t be able to solve this problem on your own - you still won’t be able to explain to your neighbors that their actions are only aggravating the situation. As a solution to the problem, you can install an additional boiler that runs on a different fuel.
Error codes for baxi gas boilers
Baksi gas boilers are reliable and durable and compare favorably with other companies. But, despite many advantages, they have some breakdowns. Let's look at the error codes that appear in Baxi gas boilers.
№№ | Meaning | Problem |
E01 | No ignition | - gas inlet pressure is not normal - the ignition unit wire is broken - the flame detector electrode is faulty or incorrectly positioned - the gas valve is faulty - the electronic board is faulty |
E02 | The overheating safety thermostat has tripped | - there is no water circulation in the primary circuit (the pump is blocked or the heat exchanger is clogged - the limit thermostat is faulty - the wiring of the limit thermostat is broken - the temperature sensor on the heating supply is faulty - the electronic board is faulty |
E03 | Board configuration error | Parameter F43 is not set correctly (Main 5, Eco Compact) |
E03 | Safety thermostat (draft sensor)/pressostat – draft sensor triggered | MainFour, EcoFour, FourTech, Luna, Nuvola, Eco Compact |
E04 | Error due to lack of ignition/frequent flame failure | -Cm. E01 - See E42 |
E05 | Temperature sensor on the heating circuit supply is faulty | - the heating supply temperature sensor is faulty (open circuit or short circuit) - the heating supply temperature sensor wiring is broken or in a short circuit |
E06 | DHW temperature sensor faulty | - DHW temperature sensor is faulty (open circuit or short circuit) - DHW temperature sensor wiring is broken or short-circuited |
E07 | Exhaust gas temperature sensor faulty | - the flue gas temperature sensor is faulty (open circuit or short circuit) - the flue gas sensor wiring is broken |
E08 | Error in flame signal amplification circuit | Electronic board not grounded or faulty |
E09 | Error in the gas valve emergency protection circuit. | - the electronic board is faulty - the gas valve is not connected correctly |
E10 | No signal from the hydraulic pressure switch | - pressure in the heating circuit < 0.5 bar. — the hydraulic pressure switch is faulty — the wiring of the hydraulic pressure switch is broken |
E11 | The low-temperature circuit overheating safety thermostat has tripped (if equipped) | |
E12 | No signal from differentiated hydraulic pressure switch | |
E13 | The contact of the differential hydraulic pressure switch is damaged | |
E18 | The function of filling the system with water is active | |
E19 | Failure when filling the system | |
E22 | Trip due to voltage drop | — supply voltage < 162V (the boiler restarts automatically at a voltage >168 V) — the electronic board is faulty. |
E25 | Maximum boiler temperature exceeded/no water circulation | - the pump is blocked or the heat exchanger is clogged - there is air in the system - the temperature sensor on the heating supply is faulty - the electronic board is faulty |
E26 | Overheating of water supply to the heating circuit | See paragraph E25 |
E27 | Incorrect position of the DHW temperature sensor | — the clamp for fastening the DHW temperature sensor has become disconnected from the pipe — the DHW temperature sensor is faulty. |
E31 | Error in data transfer between the electronic board and the removable control panel | |
E32 | Presence of scale in the heat exchanger | |
E35 | Parasitic flame (flame error) | - the electronic board is not grounded - the flame detector electrode is faulty or incorrectly positioned - the electronic board is faulty |
E36 | Exhaust gas temperature sensor faulty | - the flue gas temperature sensor is faulty (short circuit) - the wiring of the flue gas temperature sensor is short circuited |
E40 E41 | The chimney/air duct is clogged or the gas inlet pressure is too low | - gas inlet pressure is not correct - gas valve modulator wires are not connected - flame detector electrode is faulty or incorrectly positioned - flue gas temperature sensor is faulty or incorrectly positioned - chimney/air duct is clogged - gas valve is faulty - electronic board is faulty |
E42 | Flame failure | - the fan does not work (faulty or does not receive power supply) - the chimney/air duct is completely clogged - the electronic board is faulty |
E43 | The chimney/air duct is clogged or the gas inlet pressure is too low | — See paragraph E40 — E41 — supply voltage < 180 W (the boiler restarts automatically at voltage > 185 W, otherwise you must press the “R” button) — electronic board is faulty |
E50 | Exhaust gas temperature sensor has tripped | - flue gas temperature > 180°C - insufficient heat exchange on the primary heat exchanger - flue gas temperature sensor faulty - electronic board faulty |
E55 | Gas valve electronic adjustment not completed | After replacing the electronic board, the electronic adjustment of the gas valve was not carried out |
E62 | Flame signal or flue gas temperature does not stabilize | - the flame detector electrode is faulty or incorrectly positioned - the flue gas temperature sensor is faulty - the electronic board is faulty |
E65 | The chimney/air duct blockage check function turns on too often | — See paragraph E40 — E41 |
E80-96 | Removable Control Panel Error | Luna3 Luna3 Comfort Nuvola |
E96 | Reducing the voltage in the power supply network | MainFour |
E97 | The frequency (Hz) of the electronic board power supply is incorrectly set | Change frequency setpoint Hz |
E98 | Internal electronic board error | - the electronic board has been replaced, but has not yet been configured for the corresponding boiler model - parameters F03 and F12 are not configured or configured incorrectly (Main5) |
E98 | Removable control panel internal error | Luna3 |
E99 | Internal electronic board error | Luna3 Nuvola |
Flashing! | The boiler operates at minimum power | - gas inlet pressure is not correct - gas valve modulator wires are not connected - flame detector electrode is faulty or incorrectly positioned - chimney/air duct is partially clogged - gas valve is faulty - electronic board is faulty |
Flashing St | Defrost function enabled | |
Flashing | Scale has formed or there is an error in the DHW temperature sensor | - scale has formed in the DHW circuit of the primary heat exchanger - the clamp for securing the DHW temperature sensor has become disconnected from the outlet pipe - the DHW temperature sensor is faulty |
READ MORE: TOP 7 best water heaters for 2021
Is it worth repairing the boiler yourself?
A modern gas boiler is a complex and potentially dangerous system. The main danger of such units is the risk of a gas explosion in case of improper handling of the equipment or untimely elimination of various problems.
Various types of automation are responsible for maintaining the operation of the gas boiler at an optimal level. An inexperienced user is often unable to understand its structure. Therefore, to resolve serious problems, it is better to immediately invite specialists.
On your own, you can try to eliminate only visible damage and various contaminants that have led to the failure of the pipe, chimney and other parts of the boiler.
There are a number of typical problems that, in most cases, you can fix yourself. Problems will also be listed, in the event of which you can only protect yourself until a specialist arrives.
If there is a distinct smell of gas or smoke in the room, immediately turn off the boiler and leave the room, opening it for ventilation.
Call a specialist immediately. Trying to solve a gas leak problem on your own without the necessary skills is extremely dangerous and unwise.
Flame sensor failure
If the combustion sensor or gas supply pipe is broken, turn off the boiler, close all gas valves and allow the unit to cool completely.
After some time, return to the room to check for the smell of gas. If everything is fine with the draft, try turning the boiler on again. If there is no traction, immediately call a repairman.
Boiler overheating
Overheating is one of the most common problems with modern gas boilers. The reason for this may be a malfunction of automation equipment or a clogged heat exchanger.
Automation repairs cannot be handled without the appropriate knowledge.
You can clean the heat exchanger yourself. The most common materials for the manufacture of heat exchangers are copper and stainless steel. Cleaning them usually isn't a problem, but still be careful.
To clean the heat exchanger, simply remove it and thoroughly clean it with a wire brush. In the case of a copper heat exchanger, it is better to replace the brush with a metal sponge used for washing dishes.
Charge fan malfunctions
The problem with fans is their bearings. If your boiler fan stops developing the set number of revolutions, try to fix the problem as soon as possible.
To do this, remove the back of the fan, remove the stator and lubricate the bearings. Machine oil is perfect for lubrication, but if possible it is better to use a higher quality carbon composition with heat-resistant properties for this purpose.
An interturn short circuit can also cause problems with the fan. Only a specialist can cope with troubleshooting this problem. Submit the stator for repair to replace the winding, or immediately replace the faulty unit with a new device.
Chimney problems
Often, various problems in the operation of a gas heating boiler are caused by excessive clogging of the coaxial chimney.
Remove the chimney and thoroughly clean all its components of soot. This way you will not only return the previous level of efficiency of the unit, but also significantly increase the efficiency of the boiler.
Boiler equipment from the Czech company Mora TOP
has long gained popularity among Russian users. The use of high-quality materials in combination with modern technological solutions makes Mora equipment easy to operate and safe to use.
The company offers a wide range of products: wall-mounted gas and electric boilers, instantaneous gas water heaters, floor-standing cast iron boilers, various models of water heaters. And if for buyers this fact is an undoubted advantage, then for service and repair specialists it is a serious burden. The large model range of Mora equipment requires knowledge of the specifics of each line: individual features of technological schemes, nuances of connections, subtleties of maintenance and configuration. In addition to deep knowledge, boiler repair Mora TOP
requires modern equipment and the availability of suitable spare parts.
The E-Tech service center will provide high-quality repairs and service for any Mora boilers. Our center is part of the E-Tech group of companies, which provides services for the creation of various communications and the sale of climate and heating equipment. Therefore, our craftsmen can perform the entire range of activities: from design to repair and maintenance of systems of any complexity.
Wall-mounted and floor-standing gas boilers made in the Czech Republic are characterized by an excellent price-quality ratio. They are reliable, effective and safe. Their distinctive ability is stability when operating under Russian operating conditions. They continue to produce heat steadily as the pressure drops. To ensure that your Mora TOP gas boiler pleases you with warmth and hot water, do not forget about its regular service in a specialized center.
Features of some boiler models and possible malfunctions:
- Meteor wall-mounted gas boilers are equipped with a high-performance copper heat exchanger that is resistant to corrosion. If the quality of the water is low or the water treatment is insufficient, deposits may form on it, reducing the power of the boiler. Our service technician recommends inspecting and cleaning work surfaces at least once a year. One more nuance - you should not build cast iron radiators into the heating system.
- The Sirius line of wall-mounted gas boilers has the function of automatically adapting fuel consumption to current needs. Modern electronic hardware requires absolute precision in installation and configuration. Otherwise, your boiler will consume more gas than required.
We offer comprehensive maintenance and repair of gas boilers Mora TOP
. It includes diagnostics; service; replacement, if necessary, of parts and components; correction of installation errors; commissioning and other necessary activities. From us you can order both one-time assistance and long-term maintenance of wall-mounted gas boilers Titan, Sirius, Meteor, Meteor Plus; floor-standing gas boilers with atmospheric burner SA.
Wall-mounted water heating electric boilers Electra Comfort and Electra Light will delight their owners with their efficiency and ease of control. Like all heating devices of this type, they are silent and absolutely environmentally friendly. But still, sometimes repair of Mora TOP electric boilers is necessary for the smooth operation of heating equipment.
The service of Mora TOP electric boilers will allow you to maintain their high performance for the entire service life. With us you can get professional services at the best prices. In addition, we guarantee their quality and efficiency.
We use an integrated approach to the repair of Mora TOP electric boilers
- Accurate diagnostics allows you to quickly carry out all the troubleshooting work and make sure that the problem does not arise in the future.
- The use of only original spare parts and consumables during repairs and service guarantees the absolute consistency of all system elements.
- Final commissioning activities ensure the effective operation of all components, including automation.
This approach ensures stable operation of the equipment for many years and maximum safety for users.
Our technicians travel to the site for repairs and service in company vehicles equipped with modern equipment and a stock of in-demand spare parts. In most cases, the work will be completed on the first visit to the site. If the breakdown requires more serious measures, they will be carried out at our repair base.
We are authorized to work with equipment from all leading manufacturers. E-Tech masters have the necessary permits and certificates to service liquid fuel, gas, solid fuel and electric heating boilers. For more than ten years we have been helping to keep our clients' homes warm and comfortable. We value your trust and do everything possible to ensure that you stay with us for many years to come.