The main mistakes of Baksi gas boilers. Troubleshooting


About Baxi gas boilers

Baxi gas boilers have been present on the heating equipment market for quite a long time, and have shown their best performance. These heating devices are quite reliable and easy to maintain, and are assembled from high-quality components. Baxi have an adjustable flame level, which allows you to more accurately maintain the set temperature. The adjustable flame allows you to operate the boiler in a gentle mode, since the number of turns on and off of the boiler is significantly reduced. This feature allows the burner nozzle to last much longer, and also increases the life of the heat exchanger. All this is because adjustable flames reduce the frequency of heating and cooling of the heat exchanger, which has a positive effect on its service life.

Also, heating devices of this brand are famous for their efficiency, and they save not only gas, but also electricity. Baxi boilers are equipped with several temperature sensors that are located inside the boiler. But it also provides for the installation of remote temperature sensors that can be installed from the street side. With this arrangement of sensors, the boiler itself will respond to changes in air temperature outside the window and select the most optimal operating mode.

Despite the many innovative technologies used in heating devices of this brand, Baxi boilers are famous for their light weight and compactness. Even the floor-standing units from this manufacturer are quite light and small-sized. Baksi boilers are incredibly reliable, since all systems of this device are controlled by an electronic control unit. The electronics monitor all parameters of the boiler’s operation, and if the slightest malfunction occurs, the boiler’s operation stops and the error code is displayed on the liquid crystal display. Each code encrypts information about a particular malfunction, and decoding this code allows you to quickly identify the malfunction and eliminate it. Errors come in the following names.

Error e01

Malfunction e01 of Baksi boilers indicates a malfunction in the ignition system. This error is generated by the Baxi sensor, which monitors the flame. The error code can be reset manually, and to do this you need to hold down the “R” button. After 3-5 seconds have passed after pressing and holding this button, the boiler should start. If the flame does not appear and error E01 is displayed again on the screen, then only one thing will help in this situation - calling a boiler repairman. An error with this code can be caused by several reasons. This could be a failure of the ignition system, as well as incorrect operation of the electronic control unit. There have also been cases where this malfunction occurred due to an incorrectly adjusted gas valve. This error can also be caused by:

  • weak draft in the chimney;
  • low gas pressure.

Let's take a closer look at the reasons why error e01 occurs on Baxi boilers, and how to eliminate it. This error is sometimes very difficult to fix, since it can be caused by many factors. This malfunction is associated with difficulty igniting. On some models of boilers from this manufacturer, the electrode also contains a flame sensor, and this combination sometimes does not work correctly.

When the ionization current, which passes from the electrode through the burner to the ground loop without any obstacles, then the ignition works without any deviations. The control board records the parameters of the ionization current. If its strength is in the range from 5 to 15 microamps, then this can be considered the normal operating mode of the ignition system. When for some reason the ionization current strength deviates from the norm, the electronic control unit of the boiler records these deviations, and the Baxi gas boiler is blocked with error e01.

This error also appears if the contact of the electrode with the control board is broken. Also, if error e01 occurs, you should immediately check the gas pressure in the line. For natural gas, the pressure should not be lower than 2 mbar, and for liquefied gas - 5-6 mbar. The pressure can also be adjusted with a special nut located on the gas valve. It is also necessary to thoroughly check the operation of this valve - measure the resistance of the coils with a multimeter. The first coil should have a resistance of 1.3 kOhm, and the second - 2.85 kOhm.

The conductor that connects the gas valve to the electronic board may contain a diode bridge, which can also fail. This is a feature of some Baxi boiler models and the diode bridge should also be checked with a multimeter. You also need to check the resistance of the electrode itself. It should not exceed 1-2 Ohms. Also, the edge of the electrode must be at the required distance from the burner. This distance should be 3 mm.

Error e01 may also appear if ignition occurs, but the flame immediately goes out. This may be caused by reversed polarity on the 220 volt plug. By turning the fork 180 degrees, you can get rid of problems with ignition. These problems can also be caused by a ground fault. The voltage between phase and neutral phase and ground must be the same. The voltage between zero and ground should be no more than 0.1 Volt. If this parameter is violated, this may cause fault e01.

You also need to make sure that the gas line is isolated from the boiler. This line may carry a small electrical potential, which can cause a malfunction of the heating device. For insulation, a special dielectric spacer is used, which is placed between the gas pipe and the boiler.

Errors in Baxi Eco gas boilers - Why they appear and how to fix them

_______________________________________________________________________________

Error E01 - Shows that there is no ignition. The fault notification comes from the flame control sensor. Such an electrode sensor detects the presence of a flame and stops the operation of the Baxi Eco 3 Compact boiler during limited combustion of the main burner or when there are difficulties with gas supply. The operation mode stops after 3 unsuccessful starts. To return to work, you need to hold down the Reset button. Gas valve failure - The operation of the gas valve is controlled by an electronic board. Diagnosis of this component is carried out by determining the voltage and resistance. If the values ​​deviate from the standard specifications, the valve should be replaced. There is no gas flow into the system - The gas distribution circuit has a valve that closes the gas flow. Based on this, a failure to start the unit may occur due to a closed tap. Weak contact or no pulse detected from the flame control sensor. The control board has a malfunction - When the ignition cycle is completed successfully, but the device suddenly goes out anyway, it is possible that the electronics cannot see the flame. Based on this, it is necessary to diagnose it. Error E02 - Overheating of the Baxi Eco 4S boiler. The unit is blocked. The overheating protection thermostat turned on - The overheating thermostat, like the temperature sensor, is mainly located on the outlet tube of the primary heat exchanger. The main purpose of the thermostat is to ensure the safety of the device from elevated temperatures. A failure occurs due to problems in the thermostat, temperature sensor, as well as problems in the main circulation circuit. The temperature sensor is faulty - The control board is receiving an incorrect signal or the contact between the control board and the sensor is broken. The overheating thermostat has failed - When the sensor is operational, but there is a real overheating of the coolant, then most likely there is a violation of the circulation of the coolant in the heating circuit. The primary heat exchanger or the filter element of the heating circuit is clogged (weak circulation means high heating of the coolant). Error code E03 - Weak traction. In order to ensure stable and reliable operation of the device, it is necessary to organize a draft to remove combustion products so that they do not enter living quarters. The smoke output is monitored by electronics, and if certain problems appear, the draft sensor-relay is triggered and the device will be blocked. The main reasons that may result in a lack of draft are: insufficient diameter of the chimney duct, inaccuracy during installation, clogging, ice on the inner wall. A narrowing of the diameter of the outlet channel entails a lack of traction. The length of the chimney pipe is exceeded. We advise you to carefully study the installation instructions for the device and fulfill all the necessary requirements. An excessively long straight section of the chimney pipe leads to a weakening of the required draft. Problem with the pneumatic traction sensor - If a vacuum occurs in the inlet tube, a faint click will be noticeable. There is no contact between the control board and the draft sensor, there is condensation, as well as incorrect connection of the tubes to the pneumatic relay. Damage to fan parts - The fan impeller is clogged. Lack of sufficient lubrication of the fan shaft, which is why it does not increase the required speed. No contact between the electronic board and the fan. Error E05 - Problems with determining the temperature by the heating system sensor. This code indicates that the heating circuit temperature sensor has failed or the permissible temperature has risen. Damage to the heating circuit temperature sensor circuit - This problem occurs when the connection between the temperature sensor and the electronic board is interrupted, or the temperature value is below normal. 5 seconds after recognizing an accident, the wall-mounted boiler Baxi Eco 5 Compact will resume normal operation if the problem occurred spontaneously. It is necessary to make sure that there is no moisture on the sensor connector and the electronic board connector. If there is no moisture, the sensor must be replaced. There is a short circuit in the temperature sensor of the heating system - This malfunction can occur after a short circuit in the contacts of the temperature sensor or the liquid temperature is higher than the recommended one. First you need to measure the resistance of the sensor. If the resistance characteristics differ from the nominal ones, the sensor should be replaced. If replacing the temperature sensor does not give the desired result, change the electronic board. Error E06 - Failure to operate the DHW temperature sensor. This indicates a malfunction in the DHW temperature sensor or the recommended temperature has risen. Probable causes of this malfunction: the temperature sensor for hot water supply is defective. The contact between the electronic board and the DHW temperature sensor has been broken. The control board has burned out. When the DHW temperature sensor is working and is connected stably to the control board, although at this moment the device displays an error, then it seems that the electronic control board has failed. Error code E10 - Indicates low pressure in the systems. The main factors that cause this malfunction are: low coolant pressure in the heating circuit. The contact between the control board and the pressure sensor is broken. The pressure switch has failed. First you should check the pressure gauge values. Very often, the problem is eliminated by using a feed tap, which is installed to fill the system with coolant. When the problem occurs again, there may be a water leak. The circulation pump, main heat exchanger, excess pressure relief valve, damaged gaskets, make-up valve and other parts may be leaking. You can visually identify leaks in hydraulic units and components. Code E25/E26 - Damage to the circulation pump or there is an air lock in the heating system. Error code E35 - Refusal to ignite. This may occur if the ignition mechanism does not work or if the burner flame is extinguished. It is necessary to inspect the connections between the ignition unit and the flame sensor, and also between the board and the gas valve. The main cause of flame failure may be unsatisfactory draft. The Baxi Eco 3 Compact gas boiler is in operation. Lately, the E 01 ignition error code comes on almost every day. After restarting with the reset button, the device sometimes starts satisfactorily, but this does not happen often. I removed the air intake cover a few days ago and it works much better. What's wrong? When the smoke exhaust error is displayed, you must open the protection covers. This will promote air flow from the room. Next, check the chimney pipe for ice and, if necessary, clean it. In the event of a combustion emergency, it is recommended to check whether there is gas flow into the room. Error E05 is constantly displayed on the boiler. Help me figure out what it notifies about? This code indicates a malfunction of the NTC heating temperature sensor. Perhaps it needs to be replaced. Why did the Baxi Eco double-circuit gas boiler not turn on? And it also regularly shows error E02. How to fix this? This failure usually appears due to some problems with the thermostat, temperature sensor, and also when there is a problem with the main circulation circuit. It can be assumed that there is overheating of the liquid in the heat exchanger. If the temperature sensor and thermostat are not damaged, then the problem is with the control board. We recommend that you change it. Why can’t the device start and error code E10 is displayed? The pressure in the system is normal, there are no leaks. I unplug it from the socket, but the problem does not go away. What is the cause of the problem? This situation may indicate low water pressure in the heating circuit. In case of such a malfunction, it is recommended to check the pressure switch. Apparently it's broken. The malfunction of the unit is as follows: the hot water supply is set to 40 degrees. If you use hot water, the burner does not light up for long and then goes out. This cycle occurs regularly. Either cold water or warm (not hot) water flows from the mixer. Sometimes error code E02 is issued. What is the problem? This circumstance indicates that there is overheating in the DHW system. We assume that the heat exchanger is clogged with dirt, and that the thermostat has settings different from those recommended. I have the following problem. When igniting, the device displays error E35 (flame failure). If you restart it, it turns on normally, but only the burner lights up, strange clicks are heard, and then an error is displayed. I changed the ionization electrode, washed the flow sensor and removed the ground from the plug, but there was no improvement. What happened? This problem can occur in several cases. Damage to the control electrode. Difficulties with gas supply. The electronics board is faulty. The device spontaneously interrupted operation and displays code E 10. What happened? There is no water in the unit or the pressure switch is faulty. First fill the system with coolant. The unit stops working with error E03 displayed. Cleaning and blowing helps for a short time. What could it be? This situation indicates insufficient draft, and it is necessary to check the chimney system. It is likely that the membrane is stuck. Otherwise, we recommend contacting a service organization for a thorough inspection of the unit and then it. The wall-mounted boiler Baxi Eco 5 Compact works at home. Error E06 started to appear. The device itself does the work; the temperature of the coolant is set by a manual switch. During its installation, overheating apparently occurred, since the automatic mode was started based on temperature. There is no outdoor air temperature sensor. What is the reason? Most likely, the hot water temperature sensor has failed. Sometimes the electronics board is faulty. The device performs its functions for about 4-5 minutes, then the burner goes out and error E03 appears. It glows for no more than a minute, the gas burner turns on again to ignite, and the unit operates normally for another five to six minutes, and so on many times. This code, judging by the instructions, means that the draft sensor is triggered, but the chimney is not contaminated and exhaust gases come out normally. I just can’t figure out what is causing the problem? In a particular case, the probable reasons for the lack of traction may be: breakdown of the traction sensor. Lost contact between the electronic board and the traction sensor. The presence of condensate, as well as incorrect connection of the tubes to the pneumatic relay. There is a problem with the fan. Presumably it runs at low speeds.

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

  • Gas boilers
  • Electric boilers
  • Boiler error codes
  • Troubleshooting boilers
  • Gas water heaters
  • Malfunctions and repairs of geysers
  • Water heaters
  • Troubleshooting water heaters
  • Repair of indirect heating boilers
  • Troubleshooting electric convectors

_______________________________________________________________________________

_______________________________________________________________________________

  • BAXI ECO FOUR

Heating system control. Installation. Connection. Transfer to another type of gas. Adjustment devices and protection devices.

  • BAXI LUNA

Peculiarities. Installation and assembly. Automation components.

  • BAXI MAIN FOUR

Technical specifications. Installation. Adjustment and checking. Maintenance.

  • BAXI SLIM

Adjustment and protection. Installation and assembly. Pressure setting. Maintenance.

_______________________________________________________________________________

_______________________________________________________________________________

  • BAKSI - REPAIR

After starting, a malfunction appeared. It doesn’t want to turn on, it worked for two years, now the whole display lights up, just like when the boiler is turned on, when the self-diagnosis mode is in progress, then it clicks, turns off for miles and seconds and turns on the whole display again. It turned on once, but it gives error E10 water pressure, although the pressure in the system is 1.5 atm. Tell me, what could it be?

  • BAXI - OPERATION

In operation, the Baxi main four 240 boiler shuts down with error E35 (stray flame). Tell me what to do? First season in operation.

  • BAXI - SETTINGS

We installed and connected the Baxi Fourtech 24 F boiler. What cold water pressure is allowed at the inlet to the DHW device?

  • BOSCH - REPAIR

Bosch 6000 24 kW boiler, single-circuit with built-in three-way valve. The boiler sensor does not see it and gives an error. Tell me how to do it so that it doesn’t give an error and works normally for both the heating and the boiler?

  • BOSCH - ADJUSTMENTS

If you turn off the DHW flow sensor, maybe it will be possible to reprogram it into a single-circuit device through menu L3?

  • ARDERIA - REPAIR

We installed an Arderia esr 2.13 ffcd boiler. If my coolant pressure drops slightly by a couple of notches over 2-3 days, could the reason be a faulty three-way valve (there are no leaks from the radiators)?

  • ARDERIA - ADJUSTMENTS

The gas boiler Arderia 2.35 is in operation. Tell me about reducing power. I heard something about modulation, fan speed, etc. Is it really possible to reduce power?

_______________________________________________________________________________

  • BUDERUS FLOOR

We installed and connected the Buderus Logano G234-WS-44 kW boiler, automatic Logomatic 4211. Heating is based on cylinders without hot water, and the jets for reduced gas were also replaced. We survived the winter, the cylinders were replaced, all without problems. Then in the spring, when the outside temperature was +16+18, the boiler began to turn off for a long time and when turned on, it began to display a burner error on the screen and the red button light on the front wall came on. We pressed the button, turned the power back on and everything worked. This happened several times, then the boiler was turned off completely for the summer, what could be the problem?

  • BUDERUS WALL

In the single-circuit Buderus 072, is the BKN coil circuit heated by the same heat exchanger as for heating or the same as on the 2-circuit one that is used for DHW?

  • VAILLANT - REPAIR

Tell me, for Vaillant wall-mounted gas boilers, are there real/actual differences for the better in the new generation turboTEC plus VU/5-5 compared to /3-5?

  • VAILLANT - ADJUSTMENTS

There is a malfunction in the boiler, the green LED (power) is flashing, the instructions say that the thermal protection has tripped, the green indicator is flashing, even if nothing is connected to the board. How to fix? I checked all SMD resistors and transistors, everything is fine.

  • DAEWOO

In operation there is a double-circuit gas boiler Daewoo Gasboiler with an electronic panel. When the DHW is turned on, the heating heats up, the operating mode is summer. I removed the three-way valve, there is no dirt or wear. It seems that the board does not control the three-way valve. How to check?

  • ELECTROLUX

The Electrolux Basic Xi ​​wall-mounted boiler has been installed and connected. A problem began that the boiler stopped seeing the flame and turned off the gas supply after 7-8 seconds. And after 3 attempts it gave error E1. How can I fix it?

  • KOREA STAR

Koreastar boiler malfunction. The heating works perfectly, the hot water comes intermittently, when you turn on the hot water tap, cold water comes out first, then boiling water. After a few seconds it’s cool, then boiling water again. What could be the problem?

  • FERROLI

Malfunction of the Ferroli Domiproject 24 boiler - I set it to 60-70 degrees, it switches to minimum combustion, does not turn on, does not turn off. Restart is unstable. No pattern emerges. What to do?

  • JUNKERS

In operation, a Junkers euroline gas boiler, when hot water is turned on, gas ignites, then goes out, and so on several times. If you turn it on while the heating is running, the water heating starts immediately. Tell me, please, what could be the problem?

  • NAVIEN

Tell me about the adjustments of the gas boiler Navien Ace 16 turbo remote control v1.3. It is not possible to adjust the fan run-on. I set it to 30 seconds, but still 2 minutes. spins.

  • OASIS

Malfunction of the Oasis ZRT18 boiler. The unit starts, the gas lights up, then goes out. It lights up again and then goes out (this happens three times). Then it lights up and works fine. It doesn't give any error. What is the reason?

  • SAUNIER DUVAL

Malfunction of the Senor Duval gas boiler - the water pressure sensor shows 0.0, the indicator flashes red, the hot water does not heat up, but the water pressure in the apartment is good. How to fix the problem?

  • VIESSMANN

Where should a condensate trap be installed in a coaxial chimney? The boiler wh1d with a closed combustion chamber is located at a distance of 1 m from the wall.

  • WESTEN

Problem starting the Westen Pulsar D boiler. Piezo ignition works, but there is no flame, error E01 after a crackling sound. I moved the fork around.

  • BERETTA

The Novella floor-standing gas boiler is blocked - the green lights on the panel are on and nothing else happens. How to fix?

  • ARISTON

An Ariston gas wall-mounted boiler has been installed and connected, which does not hold pressure at all: while cooling the heated water, the pressure drops to zero, although water is regularly filled. What about the pressure?

  • SIME

Metropolis dgt 25 bf boiler malfunction. The hot water supply has stopped working, the heating is working, it does not display an error. What do you advise?

  • SOLLY

Please tell me how to solve the problem. The Solly Standard boiler, whenever you try to turn it on or hot water, displays a GS error.

  • WOLF

Wolf boiler in operation. Lately it has begun to behave strangely: during the pause between starts, it turns on the burner for one second five times, and 70 degrees appears on the display. Where to look for a problem?

  • ACV

ACV Wester Line works very unstable: it often crashes, makes a characteristic knock and stalls when starting, but at times everything is fine. The unit is almost new, what's wrong with it?

  • DEMRAD

In the gas boiler Demrad, the gas supply to the burner stopped. The piezo element clicks, but there is no ignition. There is nothing wrong with the gas stove, there is gas. What is the reason?

  • KITURAMI

The Kiturami world boiler is malfunctioning and stops periodically. I clean the flame sensor and the unit works fine for a while, but soon the same thing happens again. He also began to smoke heavily. Maybe the problem is that the chimney is short, and it needs to be lengthened?

_____________________________________________________________

  • IMMERGAZ - ERRORS

Errors of Nike Star, Eolo Star/Mini, Mythos boilers. Malfunctions of boilers with the possibility of automatic unlocking.

  • IMMERGAZ - REPAIR

My boiler systematically raises the temperature to 80 degrees in winter mode. I called the repairman three times. He said that many models have this problem and suggested installing a programmer, but it’s not certain that it will help. Tell me how to solve this problem and will this programmer help?

  • AOGV

Models 11.6; 17.4; 23.2; 29.3 kW. Specifications. Control elements of the automation unit. Installation and maintenance. Malfunctions and their elimination.

  • AOGV - REPAIR

The AOGV gas boiler was installed and put into operation. Problem with hot water supply. The heat exchanger was washed. Less than a month has passed and the water is not flowing again. We put a filter on the water, but time passed, and again there was no hot water. What kind of breakdown could this be?

  • AGV

Installation and installation. Start-up and adjustment. Malfunctions and ways to eliminate them.

  • AKGV

Technical specifications. Installation and connections. Startup and operating procedure. Automatic adjustments.

  • NEVA LUX

The boiler Neva Lux 7023 is malfunctioning. It gives error E7 twice a month. But after reboot it still works. Now it gives error E6. It will work for 15 minutes and turn off. What could it be?

  • ROSS

Design and automation unit. Ignition order. Malfunctions and repairs.

  • ATEM ZHYTOMYR

Tell me, is it possible that due to low gas pressure the Atem Zhytomyr boiler goes out, a click occurs and goes out. What is the problem? Is it possible to temporarily disable automation and how?

  • LEMAX

We installed a Lemax KSG-12.5 Premium gas boiler. After turning off the main burner, a clicking sound occurs after a couple of minutes, what is the reason? Tell me?

  • KEBER

A KS-G gas boiler of 250 sq.m. was installed and connected. m. When ignited, it does not turn off, the temperature rises, if I am not mistaken, automatic Arbat 1. The flame is not regulated - it is too large. What to do?

  • LIGHTHOUSE

I installed the Mayak gas boiler and connected it. It works fine. But the reason is this. When it works on unit it squeaks a lot, if you turn the knob 2-7 the squeak disappears. Tell me, what could it be?

  • DANKO

We installed and connected a Danko gas boiler with automatic Kare, it works great on the igniter, but as soon as you add power to the burner, it goes out completely, yesterday it went out within 5 minutes, today it works for about 20 minutes and goes out completely. Has anyone encountered this problem?

  • GAZLUX

The gaseko 18 boiler is in operation. When hot water is turned on, the pressure in the system drops after replenishment, the pressure reaches 3 bar. Have to reset. What's wrong, how to fix it?

  • NOVA FLORIDA

Water often boils in the boiler, causing it to fail due to overheating. The heat exchanger was recently washed, the system is not clogged. What's the matter?

  • RINNAI

Rinnai 167 RMF boiler malfunction. Recently I started showing error 14. How can I fix the problem?

  • CELTIC

The Celtic DS boiler heats up to 45 degrees and sits all day, does not turn off and does not heat the batteries, sometimes it shows error A3. How can I fix this problem?

  • MORA

The hot water pressure in the Mora Top boiler has dropped. What is the reason?

  • MASTER GAS SEOUL

The Seoul gas wall-mounted boiler stopped turning on due to a no-ignition error. How can it be eliminated? What exactly went wrong?

Error e02

Error code e02 indicates that for some reason the Baxi thermostat has tripped. If you hold down the “R” button, which is located on the boiler control panel, for 3-5 seconds, this error should go away. If after these manipulations this malfunction continues to appear on the display, then something serious has happened, and in this case you should also contact a service center. A malfunction with this code indicates that for some reason the Baxi gas boiler is overheating or the temperature sensors are not responding correctly to the temperature of the coolant. Incorrect temperature detection by the sensor can also be caused by weakened circulation of water or antifreeze in the heating circuit. There have been cases where foreign objects isolated the temperature sensor from the coolant, and therefore the sensor physically could not measure the temperature correctly, since it was isolated from water.

Error e03

This error can occur in a situation where, for some reason, the pneumatic relay does not work correctly. Also, an error code e03 may appear if the traction sensor is faulty. Also, this malfunction can occur in a situation where, for some reason, there is difficulty in removing combustion products. This may be due to:

  • improper installation of the chimney;
  • chimney blockage;
  • failure of the exhaust turbine;
  • complete failure of the pneumatic relay.

The Venturi tube, which is used to measure the draft force in the smoke exhaust duct, may also be faulty. When the turbine starts, the pressure in the chimney changes, and this change is captured by the Venturi tube. The tube is connected to a pressure switch in which the membrane is located. The membrane reacts to pressure changes, and its movement closes or opens the contacts of the microswitch of the pressure sensor. Incorrect operation of these elements can cause error e03 to appear.

You also need to check the turbine itself. First of all, the presence of free rotation of the shaft is determined, and then the fan itself is checked. The presence of voltage at the terminals of the wire that comes from the electronic board is also checked. The windings of the turbine electric motor are also checked. Their resistance should be in the range from 38 to 48 ohms. If the resistance does not meet these parameters, the fan should be replaced.

Along with the turbine, you need to check the condition of the chimney and the correctness of its installation. The air relay must also be carefully checked for operation. You can use a pressure gauge to check.

Also, the cause of error E03 in Baksi gas boilers may be poor contact on the connectors that connect the electronic board to the turbine and relay. Poor contact can be caused by oxidation, which can occur when moisture gets into the connector.

Wall-mounted (mounted) double-circuit gas boiler Baxi: other faults and their elimination

When using the wall-mounted version, other problems may occur. They are not very common, but the device owner needs to know about them:

  • E111 - appears if the coolant temperature reaches 95 degrees. To correct this, press the Reset button and hold it down for several seconds;
  • E129 – if the fan rotation speed drops below the permissible threshold. You won’t be able to fix it yourself; we recommend calling a technician;
  • E153 – when the “Reset” button is accidentally pressed. You can restore previous values ​​by holding the button pressed;
  • E154 – when liquid circulation stops. To find out, you will need to call and submit a request to the service center.

The boiler does not start

If the equipment cannot be started, it can be assumed that the reason is an incorrect electrical connection. This is possible with the Baxi Main 24 fi model. The electrical part cannot start the equipment if the phase and zero are incorrectly positioned. With this option, the display shows e01.

To resolve this you will need to take the following steps:

  1. check the connection and, if necessary, swap the wires;
  2. remove air from the system;
  3. if necessary, add coolant.

After completing the steps, you need to restart the equipment and make sure that the e01 code disappears and is not displayed on the display.

It is impossible to turn on the heating at full power


Thermostat without display This situation has several explanations.
The main reason is incorrect setting of the pressure regulator. Another option is the occurrence of problems in the functioning of the diode bridge or valve. When such problems occur, e01 will be present on the screen. First of all, you need to check the settings and, if necessary, make the correct adjustments. If the problem is with the operation of the components, then most likely they will need to be replaced.

After starting the boiler it switches off

With such a problem, e01 will also be displayed on the display of the Baxi gas boiler. The main cause of this problem is low pressure in the gas line. If there are frequent interruptions in the main gas pipeline or the pressure is not stable, it is recommended to set the value to 5 mBar. It also happens that the heating does not turn on and the gas boiler does not give an error. In such cases, you should contact specialists.

The heating system is not at sufficient temperature

The main cause of the problem is an incorrect configuration. Typically this refers to setting the required thresholds. To eliminate the breakdown, it is necessary to adjust the parameters, adhering to the recommended values.

The equipment does not support the required parameters

Most often, the reason for this behavior is a problem with the electronic board, which is responsible for controlling the electronics.

Another option is a malfunction in the gas supply valve. It can be difficult to resolve the problem on your own. It may be necessary to test the performance of the board; if necessary, you will have to replace the non-working unit.

Sensors show incorrect value

In most cases, the cause of this behavior is the failure of one or more sensors. To return the equipment to working condition, you will need to find out which sensors have failed and replace the non-functioning components.

Popping sound when heating is turned on

If there is a pop when the equipment starts up and if Baksi does not light up immediately, then pay attention to the following possible options:

  1. inconsistent pressure of blue fuel in the line. Error e01 appears;
  2. the distance between the igniter does not correspond to the established parameters;
  3. check the intensity of smoke emission.

Recommended Action: Lower the minimum limit to 5 mbar. If the recommended gap does not comply, adjust it. If there is excessive draft, adjust the intensity using the damper.

Temperature drop

The reason may lie not only in the functionality of the equipment. If such a situation arises and the gas consumption of the Baxi Main24 fi boiler is high, we advise you to check the functionality of the radiators and pipes. Pay attention to the filters; they may have accumulated rust or other impurities that interfere with the free movement of fluid in the system. From the presented material it is clear that many errors can be corrected independently. The fix does not require any experience or the use of expensive tools. But even if you can’t fix the situation yourself, using the information received, you can provide the technician with the necessary information over the phone. This will help the specialist take with him the necessary tools and spare parts.

Error e10

Malfunction e010 occurs when the signal from the hydraulic pressure switch disappears. An error with this code may be caused by the operation of a sensor that monitors water pressure. There have been cases where an error with such a code occurred when the contact between the relay and the electronic control board was lost.

There are four main causes of error e10:

  1. Leaks in the heating system.
  2. Failure of the expansion tank, or lack of air in it.
  3. Failure of the water pressure sensor in the heating circuit.
  4. Clogged “oblique” filter on the return line.

What could be the reasons for the error?

Here are the most likely reasons for the lack of draft in a gas boiler:

insufficient diameter of the exhaust channel (chimney) - design error, contamination with dirt, icing of the inner wall. The diameter of the chimney has decreased - the draft is insufficient.

exceeding the permissible length of smoke exhaust pipes. It is necessary to familiarize yourself with the manufacturer’s recommendations for installing the boiler and check that the necessary requirements are met. A horizontal section of the chimney pipe that is too long will result in a lack of necessary draft.

The pneumatic relay is faulty - the traction sensor. It is checked by the presence of a characteristic click when a vacuum is created in the supply tube (you can simulate it yourself).

missing or poor contact of the sensor with the board

Venturi device is faulty (melted or clogged)

the presence of condensate in the tube connecting the pneumatic relay with the Venturi device (true for boiler models without a special condensate collector)

incorrect connection of tubes to the pneumatic relay

For turbocharged boiler models:

fan is not working properly. May be due to clogging of the fan impeller, lack of sufficient lubrication on the fan shaft (does not develop the required speed)

lack of normal contact between the control board and the fan

malfunction of the boiler board (more common on LUNA (SLIM) series boilers)

Instructions for many models of Baxi boilers are also available for download on our website.

Next, we will examine in more detail possible options for eliminating the error.

Error e25

This error in Baksi boilers can also be caused by a large amount of air that has accumulated in the heating circuit. The airiness of the heating system contributes to the rapid heating of the coolant, and it is to this rapid heating that the electronics of the gas boiler reacts - it turns off the heating device, displaying error E25 on the screen. Also, the occurrence of this malfunction can be caused by a breakdown of the circulation pump, or failure of the temperature sensor. Most rarely, this error appears due to incorrect operation of the electronic control board, or lack of reliable contact between the circulation pump and the electronic control unit.

BAXI control board

Any gas boiler consists of actuators. This is a circulation pump, gas valve, heat exchanger, gas burner, ignition device, forced smoke removal system (for turbocharged models) and various sensors for monitoring the correct operation of the unit. The boiler operates fully automatically according to a pre-programmed algorithm, and the entire process is controlled by a control board. The operation of the automation of different boilers may differ, but in principle, as a rule, everything is the same. The whole process comes down to igniting the gas burner to heat the coolant and turning off the burner when heating needs to be stopped. Any gas boiler has a gas valve and an electrode. To ignite, the control board sends a signal to open the gas valve and high voltage to the electrodes. The electrodes are located with a small gap in relation to the burner and a spark, striking the body, ignites the gas. The process is absolutely the same as when igniting a household gas stove, only it occurs under electronic control. If, during the control process, incorrect signals are received from the control sensors, or do not arrive at all due to problems, the control board stops the operation of the boiler and displays an error on the display to the user, by the code of which it is possible to determine in which specific device system the problem occurred. There are different errors, some of them require eliminating the cause of their occurrence, some can simply be reset. The most common error codes are described in the boiler operating manual. Since a malfunction of the board itself cannot be ruled out, some codes in BAXI clearly indicate the need for its diagnosis and repair. It should be noted that this is a feature of BAXI. For example, Vaillant does not signal in any way about errors in the operation of the control unit itself.